Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 7.883
Filtrar
1.
BMC Ophthalmol ; 24(1): 145, 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38561680

RESUMO

BACKGROUND: The purpose of this study was to analyze myopic regression after corneal refractive surgery (CRS) in civilian pilots and to explore the factors that may cause long-term myopic regression. METHODS: We included civilian pilots who had undergone CRS to correct their myopia and who had at least 5 years of follow-up. We collected retrospective data and completed eye examinations and a questionnaire to assess their eye habits. RESULTS: A total of 236 eyes were evaluated in this study. 211 eyes had Intrastromal ablations (167 eyes had laser in situ keratomileusis, LASIK, 44 eyes had small incision lenticule extraction, SMILE) and 25 eyes had subepithelial ablations (15 eyes had laser epithelial keratomileusis, LASEK and 10 eyes had photorefractive keratectomy, PRK). The mean preoperative spherical equivalent (SE) was - 2.92 ± 1.11 D (range from - 1.00 to -5.00 D). A total of 56 eyes (23.6%) suffered from myopic regression after CRS. Comparisons of individual and eye characteristics between the regression and non-regression groups revealed statistically significant differences in age, cumulative flight time, postoperative SE (at 6 months and current), uncorrected visual acuity (UCVA), accommodative amplitude (AA), positive relative accommodation (PRA), postoperative period, types of CRS and eye habits. Generalized propensity score weighting (GPSW) was used to balance the distribution of covariates among different age levels, types of CRS, cumulative flying time, postoperative period and continuous near-work time. The results of GPS weighted logistic regression demonstrated that the associations between age and myopic regression, types of CRS and myopic regression, continuous near-work time and myopic regression were significant. Cumulative flying time and myopic regression, postoperative period and myopic regression were no significant. Specifically, the odds ratio (OR) for age was 1.151 (P = 0.022), and the OR for type of CRS was 2.769 (P < 0.001). The OR for continuous near-work time was 0.635 with a P value of 0.038. CONCLUSIONS: This is the first report to analyze myopic regression after CRS in civilian pilots. Our study found that for each year increase in age, the risk of civilian pilots experiencing myopic regression was increased. Intrastromal ablations had a lower risk of long-term myopia regression than subepithelial ablations. There is a higher risk of myopic progression with continuous near-work time > 45 min and poor accommodative function may be related factors in this specific population.


Assuntos
Ceratomileuse Assistida por Excimer Laser In Situ , Miopia , Ceratectomia Fotorrefrativa , Humanos , Lactente , Estudos Retrospectivos , Córnea/cirurgia , Ceratectomia Fotorrefrativa/métodos , Acuidade Visual , Refração Ocular , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Lasers de Excimer/uso terapêutico , Miopia/cirurgia , Resultado do Tratamento
2.
Sci Rep ; 14(1): 8386, 2024 04 10.
Artigo em Inglês | MEDLINE | ID: mdl-38600286

RESUMO

This prospective, non-randomized, comparative study aimed to compare the visual outcomes and patient satisfaction after implantations of three presbyopia-correcting intraocular lenses (IOLs) after myopic refractive surgery. It was conducted from January 2020 to December 2021 in Shanghai Heping Eye Hospital. Patients were divided into three groups based on the type of IOL implanted. The visual acuity, refractive stability, high-order aberrations, objective visual quality, spectacle independence, and visual function index 14 questionnaire scores of the three groups were compared. This study included 78 eyes of 39 patients: 26 eyes with 839MP, 26 eyes with MF30, and 26 eyes with ZXR00. Uncorrected distance visual acuity improved significantly for all three groups. For a pupil diameter of 4.0 mm, the spherical aberrations of the three groups were 0.33 ± 0.16 µ, 0.50 ± 0.08 µ, and 0.39 ± 0.10 µ, respectively. The spectacle independence for distance vision was over 90% in each group; for near vision, it was only 25% for the ZXR00 group. All three types of presbyopia-correcting IOLs improved visual quality in post-LASIK or PRK patients. However, the high incidence of photic phenomena after presbyopia-correcting IOL implantation in patients who have undergone myopic LASIK should not be neglected.


Assuntos
Lentes Intraoculares , Miopia , Presbiopia , Humanos , Presbiopia/cirurgia , Implante de Lente Intraocular , Satisfação do Paciente , Estudos Prospectivos , China , Miopia/cirurgia , Desenho de Prótese
3.
BMC Ophthalmol ; 24(1): 158, 2024 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-38600456

RESUMO

BACKGROUND: This study aimed to compare the visual outcomes of the first operated eyes with those of the second operated eyes following small-incision lenticule extraction (SMILE). METHODS: A total of 202 patients (404 eyes) underwent SMILE using the tear film mark centration method for myopia and myopic astigmatism correction. Baseline characteristics, objective optical quality, decentered displacement, induced corneal aberrations, and modulation transfer function (MTF) values were assessed. Linear regression analyzed the relationship between decentration and visual quality parameters, including corneal aberrations and MTF values. RESULTS: No significant difference was observed in objective visual quality, efficacy, and safety indexes between the two groups (all P > 0.05). The average decentered displacement for the first and second surgical eyes was 0.278 ± 0.17 mm and 0.315 ± 0.15 mm, respectively (P = 0.002). The horizontal coma in the first surgical eyes were notably lower than in the second (P = 0.000). MTF values at spatial frequencies of 5, 10, 15, and 20 cycles/degree (c/d) were higher in the first surgical eyes compared to the second (all P < 0.05). Linear regression indicated that high-order aberrations (HOAs), root mean square (RMS) coma, spherical aberration, horizontal coma, vertical coma, and eccentric displacement were all linearly correlated. Furthermore, MTF values exhibited a linear relationship with eccentric displacement across these spatial frequencies. CONCLUSIONS: There was no discernible difference in visual acuity, efficacy, or safety between the two operated eyes. Nonetheless, the first operated eyes exhibited reduced decentered displacement and demonstrated superior outcomes in terms of horizontal coma and MTF values compared to the second operated eyes following SMILE. The variations in visual quality parameters were linearly correlated with decentered displacement.


Assuntos
Astigmatismo , Aberrações de Frente de Onda da Córnea , Miopia , Humanos , Refração Ocular , Coma , Topografia da Córnea , Lasers de Excimer/uso terapêutico , Miopia/cirurgia , Astigmatismo/cirurgia , Substância Própria/cirurgia
4.
Sci Rep ; 14(1): 8732, 2024 04 16.
Artigo em Inglês | MEDLINE | ID: mdl-38627567

RESUMO

We sought to evaluate the topographic risk factors for early myopic regression after small-incision lenticule extraction (SMILE). A retrospective case‒control study was conducted, and individuals who underwent SMILE surgery were enrolled. Among them, 406 and 14 eyes were categorized into the nonregression and regression groups, respectively. The preoperative and postoperative parameters in the two groups were collected, including spherical refraction (SE), axial length (AXL) and topographic data. A generalized linear model was adopted to analyze the difference in each parameter between the two groups. After 6 months, UCVA decreased in the regression group, and SE increased in the regression group (both P < 0.05). The increase in the CCT at the thinnest point (P = 0.044), flat corneal curvature (P = 0.012) and TCRP (P = 0.001) were significantly greater in the regression group. Regarding the risk factors for myopic regression, preoperative SE, preoperative sphere power, preoperative AXL, preoperative flat corneal curvature, preoperative SA, early postoperative SE, early postoperative sphere power, early postoperative AXL and early postoperative CCT difference were significantly greater in the regression group (all P < 0.05). The SE, sphere power, AXL, preoperative flat corneal curvature, preoperative SA, and postoperative CCT difference correlate with early myopic regression after SMILE.


Assuntos
Cirurgia da Córnea a Laser , Miopia , Ferida Cirúrgica , Humanos , Córnea/cirurgia , Substância Própria/cirurgia , Acuidade Visual , Estudos Retrospectivos , Estudos de Casos e Controles , Cirurgia da Córnea a Laser/efeitos adversos , Lasers de Excimer/uso terapêutico , Refração Ocular , Miopia/cirurgia , Ferida Cirúrgica/cirurgia
5.
BMC Ophthalmol ; 24(1): 175, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38627709

RESUMO

PURPOSE: The purpose of this study was to compare the preoperative anxiety, aqueous humor monocyte chemoattractant protein-1 (MCP-1) concentration, intraoperative pain, and degree of cooperation of the first eye implantable collamer lens (ICL) surgery with the second eye surgery, of the 1-day interval group with the 1-week interval group, and to investigate the possible causes of these differences, as well as to determine the appropriate interval between bilateral eye ICL surgeries. METHOD: The study was a prospective observational study. A total of 120 patients who underwent bilateral ICL surgery at the Department of Ophthalmology, West China Fourth Hospital, Sichuan University, from July to September 2023, were enrolled. The patients were divided into a 1-day interval group and a 1-week interval group. The ICL surgery was performed on both eyes according to the schedule. Anxiety levels, aqueous humor MCP1, cooperativeness, surgical time, pain and satisfaction, and patients' estimations of the time spent in the operation were recorded for each eye. The patients were instructed to recall the intraoperative pain of the first eye surgery after the operation of the second eye. Statistical analyses (two independent samples t-test,two paired samples t-test, the rank-sum test, the chi-square test, non-parametric test with multiple independent samples) were performed to compare the differences between each score in both eyes and two groups. Furthermore, we examined the relationship between pain levels and the reproductive history of the patients. RESULTS: In the 1-day interval group, male/female is 22/52, average age is 25.24±5.00. In the 1-week interval group, male/female is 17/29, average age is 25.39±5.57. There was no statistically significant difference between the two groups. In both groups, patients were less nervous, had significantly more pain, had less surgical satisfaction, had a longer estimated operative time, and had elevated preoperative MCP1 during the second eye operation. In the second eye surgery, the patient's cooperation worsened, but it did not lead to an increase in surgical time. A significant proportion of patients, particularly in the 1-week interval group, recalled experiencing reduced pain during the first eye surgery. The 1-week interval group had a higher difference in all indicators between the bilateral surgeries. In the second eye surgery, patients in the 1-week interval group experienced more severe pain, less cooperation, longer estimated operation duration, and a greater MCP1 than those in the 1-day interval group. CONCLUSION: Patients undergoing second eye ICL surgery had decreased nervousness, increased pain, decreased cooperation, and satisfaction, and increased MCP1 compared to the first eye surgery. It is recommended that an interval of about one week should be avoided between bilateral surgeries when developing a surgical schedule to improve patients' cooperation, satisfaction, and comfort.


Assuntos
Lentes Intraoculares , Miopia , Lentes Intraoculares Fácicas , Humanos , Masculino , Feminino , Implante de Lente Intraocular , Miopia/cirurgia , Olho , Dor/cirurgia
6.
J Refract Surg ; 40(4): e229-e238, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38593259

RESUMO

PURPOSE: To evaluate the effects of topical 0.05% cyclosporine A on Ocular Surface Disease Index (OSDI) score and ocular surface parameters after small incision lenticule extraction (SMILE) for myopia. METHODS: In this study, 151 patients who underwent SMILE were randomized into the control group (71 eyes) and the 0.05% cyclosporine A group (80 eyes). Both groups received standard treatment during the 1 month after SMILE. Over the next 3 months, The control group continued standard therapy (0.3% sodium hyaluronate) and the 0.05% cyclosporine A group received additional 0.05% cyclosporine A. OSDI total and subscale scores, non-invasive tear break-up time (NIBUT), tear lipid layer thickness (LLT), and tear meniscus height (TMH) were assessed preoperatively and postoperatively. RESULTS: Compared to baseline, the OSDI scores significantly increased in both groups (P < .001). The 0.05% cyclosporine A group exhibited lower OSDI total scores after administering 0.05% cyclosporine A versus the control group (P = .026). At 1 month of follow-up, NIBUT, LLT, and TMH values significantly decreased in both groups compared to baseline (P < .05). The 0.05% cyclosporine A group exhibited higher NIBUT, LLT, and TMH versus the control group, returning to preoperative values after 2 months. Overall, the OSDI total score and NIBUT values during follow-up were not significantly different between the two groups; however, the LLT and TMH values were significantly different between the two groups (P < .001 and .041, respectively) by repeated measures analysis of variance. CONCLUSIONS: Topical 0.05% cyclosporine A was effective in relieving subjective dry eye symptoms and maintaining ocular surface stability in the early postoperative period of SMILE. [J Refract Surg. 2024;40(4):e229-e238.].


Assuntos
Síndromes do Olho Seco , Ceratomileuse Assistida por Excimer Laser In Situ , Miopia , Humanos , Ciclosporina/uso terapêutico , Miopia/cirurgia , Síndromes do Olho Seco/diagnóstico , Síndromes do Olho Seco/tratamento farmacológico , Síndromes do Olho Seco/etiologia , Lágrimas
7.
J Refract Surg ; 40(4): e239-e244, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38593260

RESUMO

PURPOSE: To explore changes in corneal epithelial thickness (CET) after femtosecond laser-assisted laser in situ keratomileusis in patients with high astigmatism. METHODS: CET was measured at every intersection of the concentric circles and specific axes using AngioVue optical coherence tomography (Angio-OCT) preoperatively and 1 month postoperatively. The average thickness of corneal central, paracentral, and peripheral regions was the mean of the points within the central 2, 2 to 5, and 5 to 7 mm areas, respectively. Correlation analysis was performed to investigate the association between CET along different axes and other preoperative and postoperative parameters. RESULTS: Forty-two eyes of 28 patients were included. CET along the astigmatic (K1) and perpendicular (K2) axes in the central and paracentral areas increased (P < .001), whereas that along the K2 axis decreased in the peripheral area 1 month postoperatively (P = .001). The amount of CET change in the peripheral area between the K1 and K2 axes was significantly different (P < .001). In the central area, the change in CET along the K2 axis was positively correlated with ablation depth (r = 0.315, P = .042) and negatively with refractive power after surgery (r = -0.347, P = .024). In the peripheral area, the changes in CET along both K1 and K2 axes were negatively correlated with ablation depth (r = -0.431, P = .004; r = -0.387, P = .011, respectively). CONCLUSIONS: Epithelial modeling differed between the different astigmatism axes after refractive surgery. The compensatory response of the corneal epithelium is more pronounced along the steeper axis. [J Refract Surg. 2024;40(4):e239-e244.].


Assuntos
Astigmatismo , Ceratomileuse Assistida por Excimer Laser In Situ , Miopia , Humanos , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Acuidade Visual , Astigmatismo/cirurgia , Miopia/cirurgia , Estudos Prospectivos , Lasers , Lasers de Excimer/uso terapêutico
8.
J Refract Surg ; 40(4): e199-e207, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38593258

RESUMO

PURPOSE: To investigate the efficacy of incorporating Generative Adversarial Network (GAN) and synthetic images in enhancing the performance of a convolutional neural network (CNN) for automated estimation of Implantable Collamer Lens (ICL) vault using anterior segment optical coherence tomography (AS-OCT). METHODS: This study was a retrospective evaluation using synthetic data and real patient images in a deep learning framework. Synthetic ICL AS-OCT scans were generated using GANs and a secondary image editing algorithm, creating approximately 100,000 synthetic images. These were used alongside real patient scans to train a CNN for estimating ICL vault distance. The model's performance was evaluated using statistical metrics such as mean absolute percentage error (MAPE), mean absolute error (MAE), root mean squared error (RMSE), and coefficient of determination (R2) for the estimation of ICL vault distance. RESULTS: The study analyzed 4,557 AS-OCT B-scans from 138 eyes of 103 patients for training. An independent, retrospectively collected dataset of 2,454 AS-OCT images from 88 eyes of 56 patients, used prospectively for evaluation, served as the test set. When trained solely on real images, the CNN achieved a MAPE of 15.31%, MAE of 44.68 µm, and RMSE of 63.3 µm. However, with the inclusion of GAN-generated and algorithmically edited synthetic images, the performance significantly improved, achieving a MAPE of 8.09%, MAE of 24.83 µm, and RMSE of 32.26 µm. The R2 value was +0.98, indicating a strong positive correlation between actual and predicted ICL vault distances (P < .01). No statistically significant difference was observed between measured and predicted vault values (P = .58). CONCLUSIONS: The integration of GAN-generated and edited synthetic images substantially enhanced ICL vault estimation, demonstrating the efficacy of GANs and synthetic data in enhancing OCT image analysis accuracy. This model not only shows potential for assisting postoperative ICL evaluations, but also for improving OCT automation when data paucity is an issue. [J Refract Surg. 2024;40(4):e199-e207.].


Assuntos
Cristalino , Miopia , Lentes Intraoculares Fácicas , Humanos , Tomografia de Coerência Óptica/métodos , Implante de Lente Intraocular/métodos , Estudos Retrospectivos , Miopia/cirurgia
9.
J Refract Surg ; 40(4): e245-e252, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38593261

RESUMO

PURPOSE: To evaluate clinical outcomes and visual quality 12 months after femtosecond laser-assisted laser in situ keratomileusis (FS-LASIK) performed with the Custom-Q algorithm for correction of myopia with or without astigmatism and compensate for age-related accommodation deficiency. METHODS: Patients who had Custom-Q FS-LASIK for myopia and myopic astigmatism with age-related accommodation deficiency were included in this retrospective study. Distance, intermediate, and near visual acuities, objective and subjective refractions, Q-factor, corneal higher order aberrations (HOAs), accommodation function, defocus curve, contrast sensitivity, and a subjective questionnaire assessing visual quality were evaluated 12 months postoperatively. RESULTS: Clinical data of 43 cases were analyzed. The mean age was 42.02 ± 1.85 years (range: 40 to 48 years). At the 12-month follow-up visit, there were 43 (100%), 42 (97%), and 33 (77%) patients who achieved a binocular uncorrected distance, intermediate, and near visual acuity, respectively, better than 20/20 separately. Defocus curves revealed better distance vision in the dominant eyes, and the nondominant eyes performed better at intermediate and near vergence (P < .001). The Q-value and corneal spherical aberration coefficient were more positive in the dominant eyes than those in the nondominant eyes (P < .001). The accommodative amplitude and relative accommodation improved binocularly (P < .001). The questionnaire demonstrated high patient satisfaction with near vision, and no one reported having severe visual disturbance. CONCLUSIONS: For myopic patients with age-related accommodation deficiency, the Custom-Q algorithm proved to be an effective way to achieve acceptable near vision without compromising distance vision. [J Refract Surg. 2024;40(4):e245-e252.].


Assuntos
Astigmatismo , Aberrações de Frente de Onda da Córnea , Ceratomileuse Assistida por Excimer Laser In Situ , Miopia , Humanos , Adulto , Estudos Retrospectivos , Acuidade Visual , Córnea , Miopia/cirurgia , Astigmatismo/cirurgia , Lasers de Excimer/uso terapêutico , Refração Ocular , Resultado do Tratamento
11.
J Cataract Refract Surg ; 50(5): 448-452, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38651696

RESUMO

PURPOSE: To develop an accurate deep learning model to predict postoperative vault of phakic implantable collamer lenses (ICLs). SETTING: Parkhurst NuVision LASIK Eye Surgery, San Antonio, Texas. DESIGN: Retrospective machine learning study. METHODS: 437 eyes of 221 consecutive patients who underwent ICL implantation were included. A neural network was trained on preoperative very high-frequency digital ultrasound images, patient demographics, and postoperative vault. RESULTS: 3059 images from 437 eyes of 221 patients were used to train the algorithm on individual ICL sizes. The 13.7 mm size was excluded because of insufficient data. A mean absolute error of 66.3 µm, 103 µm, and 91.8 µm were achieved with 100%, 99.0%, and 96.6% of predictions within 500 µm for the 12.1 mm, 12.6 mm, and 13.2 mm sizes, respectively. CONCLUSIONS: This deep learning model achieved a high level of accuracy of predicting postoperative ICL vault with the overwhelming majority of predictions successfully within a clinically acceptable margin of vault.


Assuntos
Aprendizado Profundo , Implante de Lente Intraocular , Miopia , Lentes Intraoculares Fácicas , Humanos , Estudos Retrospectivos , Miopia/cirurgia , Adulto , Feminino , Masculino , Período Pós-Operatório , Inteligência Artificial , Acuidade Visual/fisiologia , Pessoa de Meia-Idade , Adulto Jovem , Redes Neurais de Computação
12.
Klin Monbl Augenheilkd ; 241(4): 361-366, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38653303

RESUMO

The PRESERFLO™ MicroShunt (MP; Santen Inc., Osaka, Japan) is a minimally invasive bleb surgery (MIBS) manufactured to treat primary open-angle glaucoma (POAG), with lower postoperative adverse effects than with conventional filtering surgeries. We describe here the case study of a 58-year-old woman who presented with bilateral severe myopia with bilateral advanced POAG and unreached target pressure under quadritherapy, who was successfully managed by PM surgery. A review of the literature completes our observation. At presentation, the patient had a spherical equivalent of - 7.50 RE and - 7.75 LE with an IOP of 22 mmHg right and left eye (RLE) under quadritherapy, and with severe bilateral visual field loss, including scotomas within the central 5°. The patient presented with systemic hypertension treated with an antihypertensive drug. Two selective laser trabeculoplasties (SLT), performed 3 months apart, were first tried on the LE, without any change in IOP at 2 months. After considering the high risk of postoperative complications, a PM operation was proposed, with a targeted IOP in the mid-fifteens RLE. The patient's eyes underwent PM surgery with mitomycin C (MMC) MMC0.2 mg/mL for 3 minutes without any complications. The LE required 2 consecutive needlings with 1 mL MMC0.2 mg/mL. At 24 months after surgery, the two eyes gave successful results without the need for any additional medical therapy, and with well-functioning conjunctival blebs. The PM was an effective alternative to the gold standard trabeculectomy in our severely myopic patient. A comparative study between conventional filtering operations and this MIBS in highly myopic patients would confirm our observation.


Assuntos
Glaucoma de Ângulo Aberto , Humanos , Feminino , Pessoa de Meia-Idade , Glaucoma de Ângulo Aberto/cirurgia , Glaucoma de Ângulo Aberto/diagnóstico , Trabeculectomia/métodos , Miopia/cirurgia , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Resultado do Tratamento
13.
Arq Bras Oftalmol ; 87(3): e20230049, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38537048

RESUMO

PURPOSE: To investigate the association of pre-photorefractive keratectomy Schirmer-1 test value with post-photorefractive keratectomy central corneal epithelial thickness, ocular surface disease index score, and uncorrected distance visual acuity. METHODS: Patients were categorized according to preoperative Schirmer-1 value: the normal Schirmer Group (n=54; Schirmer-1 test value, >10 mm) and the low Schirmer Group (n=52; Schirmer-1 test value, between 6 and 10 mm). We analyzed ablation depth, visual acuity, result of Schirmer-1 test (with anesthesia), tear film break-up time, ocular surface disease index score, central corneal epithelial thickness, and spherical equivalent refraction. RESULTS: We found significant differences between the groups in Schirmer-1 test value, tear film break-up time, and ocular surface disease index score, both preoperatively and postoperatively (p<0.001). The preoperative central corneal epithelial thicknesses of the two groups were similar (p>0.05). After photorefractive keratectomy, the Schirmer-1 test value and spherical equivalent refraction decreased in both groups (p<0.05), and ocular surface disease index scores and central corneal epithelial thickness values increased in the low Schirmer Group (p<0.001) but not in the normal Schirmer Group (p>0.05). The postoperative central corneal epithelial thicknesses of the low Schirmer Group were significantly higher than those of the normal Schirmer Group (p<0.001). Postoperative uncorrected distance visual acuity did not differ significantly between the two groups (p>0.05). CONCLUSIONS: In patients with low Schirmer-1 test values before photorefractive keratectomy, the corneal epithelium thickened and ocular surface complaints increased during the postoperative period. However, changes in the corneal epithelium did not affect the postoperative uncorrected distance visual acuity. To reduce postoperative problems on the ocular surface in these patients, we recommend that dry eye be treated before photorefractive keratectomy.


Assuntos
Epitélio Corneano , Miopia , Ceratectomia Fotorrefrativa , Humanos , Miopia/cirurgia , Acuidade Visual , Refração Ocular , Lasers de Excimer/uso terapêutico
14.
BMC Ophthalmol ; 24(1): 117, 2024 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-38481187

RESUMO

BACKGROUND: To report a case of interface fluid syndrome (IFS) following traumatic corneal perforation repair after small incision lenticule extraction (SMILE). CASE PRESENTATION: A 23-year-old woman, with a past history of SMILE, was struck in the left eye with a barbecue prod and subsequently underwent corneal perforation repair at local hospital. Primary wound repaired with a single 10 - 0 nylon suture at the area of leakage. After the surgery, her best corrected visual acuity (BCVA) was 20/30. Four days later, she presented at our hospital with blurred vision, and interface fluid syndrome (IFS) was diagnosed. Intraoperative optical coherence tomography (iOCT) was used to guide the resuturing of the corneal perforation in the left eye, followed by anterior chamber gas injection. At the first postoperative month, the BCVA was 20/25. The corneal cap adhered closely to the stroma, the surface became smooth. CONCLUSIONS: This case illustrates that any corneal perforation following lamellar surgery, including SMILE, may lead to IFS. It is crucial to consider the depth of corneal perforation, and intraoperative optical coherence tomography (iOCT) plays a unique role in the repair procedure.


Assuntos
Perfuração da Córnea , Cirurgia da Córnea a Laser , Miopia , Humanos , Feminino , Adulto Jovem , Adulto , Perfuração da Córnea/diagnóstico , Perfuração da Córnea/etiologia , Perfuração da Córnea/cirurgia , Miopia/cirurgia , Miopia/diagnóstico , Substância Própria/cirurgia , Procedimentos Cirúrgicos Oftalmológicos , Córnea , Tomografia de Coerência Óptica/métodos , Cirurgia da Córnea a Laser/efeitos adversos , Cirurgia da Córnea a Laser/métodos , Topografia da Córnea , Lasers de Excimer
15.
Indian J Ophthalmol ; 72(4): 549-553, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38546469

RESUMO

PURPOSE: To compare the accuracy of nine conventional and newer-generation formulae in calculating intraocular lens power in eyes with axial myopia. SETTING: Tertiary eye care center, Bengaluru, India. DESIGN: Retrospective cross-sectional, comparative study conducted in India. METHODS: Patients undergoing uneventful phacoemulsification in eyes with axial length >26 mm were included. Preoperative biometry was done using Lenstar LS 900 (Haag-Streit AG, Switzerland). Single eye of patients undergoing bilateral implantation was randomly selected. Optimized lens constants were used to calculate the predicted postoperative refraction of each formula, which was then compared with the actual refractive outcomes to give the prediction errors, following which subgroup analysis was performed. The Kane formula, Barrett universal II, Emmetropia Verifying Optical (EVO) 2.0, Hill Radial Basis Function (Hill RBF) 3.0, Olsen formula, along with Wang Koch-adjusted four formulae, that is, Sanders Retzlaff Kraff/Theoretical (SRK/T), Holladay 1, Haigis, and Hoffer Q formula, were compared for intraocular lens power calculations. RESULTS: One hundred and sixty-five eyes that fulfilled all the inclusion criteria were studied. Hill RBF 3.0 had the lowest mean and median absolute prediction errors (0.355 and 0.275, respectively) compared to all formulas. In subgroup analysis (26-28, >28-30, and >30 mm), significant difference was seen only in extremely long eyes (>30 mm). The Hill RBF 3.0 formula generated the maximum percentage of eyes with refractive errors within ±0.25, ±0.5, ±0.75, and ±1 D (46%, 76.2%, 89.9%, and 95.8%, respectively). CONCLUSION: This is the first study evaluating all the formulas exclusively in the myopic eyes. Hill RBF 3 was found to be superior in accuracy to all other formulas.


Assuntos
Lentes Intraoculares , Miopia , Humanos , Estudos Transversais , Estudos Retrospectivos , Olho , Miopia/diagnóstico , Miopia/cirurgia
16.
Comput Biol Med ; 173: 108245, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38531253

RESUMO

PURPOSE: This study aimed to evaluate and optimize intraocular lens (IOL) power selection for cataract patients with high axial myopia receiving trifocal IOLs. DESIGN: A multi-center, retrospective observational case series was conducted. Patients having an axial length ≥26 mm and undergoing cataract surgery with trifocal IOL implanted were studied. METHODS: Preoperative biometric and postoperative outcome data from 139 eyes were collected to train and test various machine learning (ML) models (support vector machine, linear regression, and stacking regressor) using five-fold cross-validation. The models' performance was further validated externally using data from 48 eyes enrolled from other hospitals. Performance of seven IOL calculation formulas (BUII, Kane, EVO, K6, DGS, Holladay I, and SRK/T) were examined with and without ML models. RESULTS: The results of cross-validation revealed improvements across all IOL calculation formulas, especially for K6 and Holladay I. The model increased the percentage of eyes with a prediction error (PE) within ±0.50 D from 71.94% to 79.14% for K6, and from 35.25% to 51.80% for Holladay I. In external validation involving 48 patients from other centers, six out of seven formulas demonstrated a reduction in the mean absolute error (MAE). K6's PE within ±0.50 D improved from 62.50% to 77.08%, and Holladay I from 16.67% to 58.33%. CONCLUSIONS: In this study, we conducted a comprehensive evaluation of seven IOL power calculation formulas in high axial myopia cases and explored the effectiveness of the Stacking Regressor model in augmenting their accuracy. Of these formulas, K6 and Holladay I exhibited the most significant improvements, suggesting that integrating ML may have varying levels of effectiveness across different formulas but holds substantial promise in improving the predictability of IOL power calculations in patients with long eyes.


Assuntos
Catarata , Lentes Intraoculares , Miopia , Humanos , Refração Ocular , Estudos Retrospectivos , Miopia/cirurgia , Óptica e Fotônica
17.
Int Ophthalmol ; 44(1): 141, 2024 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-38492122

RESUMO

PURPOSE: Phakic intraocular lenses treat higher degrees of myopia not possible previously with conventional refractive surgery. The aim of this study is to report the incidence and risk factors of retinal complications after posterior chamber PIOL implantation and assess the differences in biometric parameters between patients who developed such complications versus those who did not. METHODS: This retrospective study recruited 514 patients who underwent ICL implantation to correct myopia at a tertiary eye hospital center in the Eastern province of Saudi Arabia. Follow up period was at least one year. Medical records of the patients were reviewed to obtain the required data. Associations between respondents' characteristics and retinal complications were evaluated using the Chi-squared test. RESULTS: The mean (SD) age was 27.7 (± 6.5) years ranging from 18 to 47. Laser treatment was performed in 14 cases (2.7%). Retinal complications occurred in six cases (1.2%). The risk of retinal complication was significantly higher among patients with high axial length (OR = 1.3, 95% CI 1.2, 1.4) and patients with high pre-spherical equivalent before ICL (OR = 1.09, 95% CI 1.03, 1.4). CONCLUSION: Patients with higher axial length and higher pre-spherical equivalent before ICL implantation are at high risk of retinal complications.


Assuntos
Miopia , Lentes Intraoculares Fácicas , Humanos , Adulto Jovem , Adulto , Implante de Lente Intraocular/efeitos adversos , Acuidade Visual , Estudos Retrospectivos , Arábia Saudita/epidemiologia , Refração Ocular , Miopia/epidemiologia , Miopia/cirurgia , Miopia/etiologia , Lentes Intraoculares Fácicas/efeitos adversos , Hospitais , Seguimentos
18.
PLoS One ; 19(3): e0296811, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38512912

RESUMO

BACKGROUND: To analyze vault effects of crystalline lens rise (CLR) and anterior chamber parameters (recorded by Pentacam) in highly myopic patients receiving implantable collamer lenses (ICLs), which may avoid subsequent complications such as glaucoma and cataract caused by the abnormal vault. METHODS: We collected clinical data of 137 patients with highly myopic vision, who were all subsequent recipients of V4c ICLs between June 2020 and January 2021. Horizontal ciliary sulcus-to-sulcus diameter (hSTS) and CLR were measured by ultrasonic biomicroscopy (UBM), and a Pentacam anterior segment analyzer was used to measure horizontal white-to-white diameter (hWTW), anterior chamber depth (ACD), anterior chamber angle (ACA), anterior chamber volume (ACV), CLR, and postoperative vault (Year 1 and Month 1). The lens thickness (LT) was determined by optical biometry (IOL Master instrument). The predictive model was generated through multiple linear regression analyses of influential factors, such as hSTS, CLR, hWTW, ACD, ACA, ACV, ICL size, and LT. The predictive performance of the multivariate model on vault after ICL was assessed using the receiver operating characteristic (ROC) curve with area under the curve (AUC) as well as the point of tangency. RESULTS: Average CLR assessed by UBM was lower than the average value obtained by Pentacam (0.561 vs. 0.683). Bland-Altman analysis showed a good consistency in the two measurement methods and substantial correlation (r = 0.316; P = 0.000). The ROC curve of Model 1 (postoperative Year 1) displayed an AUC of 0.847 (95% confidence interval [CI]: 74.19-95.27), with optimal threshold of 0.581 (sensitivity, 0.857; specificity, 0.724). In addition, respective values for Model 2 (postoperative Month 1) were 0.783 (95% CI: 64.94-91.64) and 0.522 (sensitivity, 0.917; specificity, 0.605). CONCLUSION: CLR and anterior chamber parameters are important determinants of postoperative vault after ICL placement. The multivariate regression model we constructed may serve in large part as a predictive gauge, effectively avoid postoperative complication.


Assuntos
Cristalino , Miopia , Lentes Intraoculares Fácicas , Humanos , Implante de Lente Intraocular/efeitos adversos , Acuidade Visual , Cristalino/cirurgia , Câmara Anterior/diagnóstico por imagem , Miopia/cirurgia , Estudos Retrospectivos
19.
Int Ophthalmol ; 44(1): 153, 2024 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-38509410

RESUMO

PURPOSE: This study aimed to measure the Raman spectrum of the human corneal stroma lens obtained from small incision lenticule extraction surgery (SMILE) in Asian myopic eyes using a confocal Raman micro-spectrometer built in the laboratory. METHODS: Forty-three myopic patients who underwent SMILE with equivalent diopters between - 4.00 and - 6.00 D were selected, and the right eye data were collected. Corneal stroma lenses were obtained during surgery, and the Raman spectra were measured after air drying. The complete Raman spectrum of human myopic corneal stroma lens tissue was obtained within the range of 700-4000 cm-1. RESULTS: Thirteen characteristic peaks were found, with the stronger peaks appearing at 937 cm-1, corresponding to proline, valine, and the protein skeleton of the human myopic corneal stroma lens; 1243 cm-1, corresponding to collagen protein; 1448 cm-1, corresponding to the collagen protein and phospholipids; and 2940 cm-1, corresponding to the amino acid and lipids, which was the strongest Raman peak. CONCLUSION: These results demonstrated that Raman spectroscopy has much potential as a fast, cost-effective, and reliable diagnostic tool in the diagnosis and treatment of eye diseases, including myopia, keratoconus, and corneal infection.


Assuntos
Cirurgia da Córnea a Laser , Ceratomileuse Assistida por Excimer Laser In Situ , Miopia , Humanos , Substância Própria/cirurgia , Acuidade Visual , Miopia/diagnóstico , Miopia/cirurgia , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Colágeno , Lasers de Excimer , Refração Ocular
20.
J Cataract Refract Surg ; 50(4): 430-435, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38523280

RESUMO

A 28-year-old nurse had an aberration-free femto-laser in situ keratomileusis (LASIK) performed for her myopia of -6.25 -0.50 × 096 and -6.75 -0.50 × 175 in the right and left eye, respectively. Corrected distance visual acuity (CDVA) preoperatively was 20/16. Preoperatively, there were no abnormalities on Scheimpflug imaging, and a pachymetry of 585 µm was measured in both eyes. Flap thickness was 115 µm. The patient was quite nervous during the surgery. Since the surgery, her uncorrected distance visual acuity (UDVA) and CDVA are suboptimal at 20/30 and 20/20 in the right eye, and 20/20 and 20/16 in the left eye. 3 months postoperatively, there is a stable manifest refraction of +0.25 -1.25 × 030 and +0.25 -0.00 × 0. The keratometric astigmatism in the Scheimpflug imaging is 1.2 diopter (D) × 114 and 0.4 D × 78 in the right and left eyes, respectively (FIgures 1 and 2). Thinnest pachymetry is 505 µm and 464 µm in the right and left eye, respectively. Her wavefront analysis shows refraction in a 6 mm zone of -0.99 -1.22 × 32 and -0.91 -0.36 × 136. The cycloplegic refraction is 1.25 -1.00 × 023 and +1.00 -0.25 × 006 (Figures 3 and 4). What is the cause of the suboptimal visual outcome in this case? What would be your treatment strategy to improve visual outcome?


Assuntos
Astigmatismo , Aberrações de Frente de Onda da Córnea , Ceratomileuse Assistida por Excimer Laser In Situ , Miopia , Humanos , Feminino , Adulto , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Aberrações de Frente de Onda da Córnea/cirurgia , Resultado do Tratamento , Acuidade Visual , Refração Ocular , Miopia/cirurgia , Miopia/complicações , Astigmatismo/cirurgia , Astigmatismo/complicações , Lasers de Excimer/uso terapêutico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...